Introduction of Electro Acupuncture Machine
The electroacupuncture machine outputs pulses in a very safe and effective manner to stimulate acupuncture points. It has low voltage, low frequency and the same frequency range as the human body. After needling, pulses will be input to the meridians of various parts of the human body, to achieve the effects of dredging the meridians, reconciling yin and yang, strengthening the body, and eliminating evil, relieving pain and relieving spasm, reducing inflammation and swelling, and enhancing disease resistance. The whole processing is safe and efficient, and the operation is simple.
The electroacupuncture therapy unit is widely used by acupuncturists, massage therapists, chiropractors, and medical doctors. Three models for choice: SHD-I, SHD-II, and SHD-III.
Features of Electronic Pulse Acupuncture Devices
SHD-I 5 Chanel Output Electro-acupuncture device
- Five-way output, adjustable in the output intensity;
- Adjustable in three waveforms: continuous wave, intermittent wave, and dense-disperse wave.
- Electrical excitation and body surface acupoint electrical stimulation therapy;
- One output line with a pin.
SHD-II 6 Channel Outputs Electro acupuncture device
- Microcomputer control
- Rated input power: 8VA.
- Adjustable in three output waveforms: continuous wave, intermittent wave, and dense-disperse wave.
- Frequency of continuous wave: 0.8Hz-100Hz adjustable.
- Pulse width: 5ms±0.1ms.
- Cycle: 6s
- Pulse intensity:
- Load impedance 250Ω, 0-18Vpp, enhancement output intensity 0-20Vpp;
- Load impedance 500Ω, 0-38Vpp, enhancement output intensity 0-44Vpp
- Electrical excitation and body surface acupoint electrical stimulation therapy;
- Self-protection function;
- Six output lines with a pin.
- Treatment time: 10 min, 15min,20 min, 25min, 30min, 40min, 50min, 60 min.
SHD-III 6 Channel Output Electro acupuncture machine
- Microcomputer control
- Rated input power: 8VA±10%.
- There are six output, each can independently adjust the intensity of the size, easy to operate.Four-way output or two-way enhanced output;
- With special knob to adjust the waveform, frequency, and output strength.
- Treatment time: 10 min, 20 min, 30min, 40min, 50min, 60 min.
- Three output pulse wave forms: continuous wave, intermittent wave, and dense-disperse wave.
- Pulse width: 0.5ms±1ms.
- Continuous wave frequency: 0.8Hz~100Hz adjustable.
- Self-protective function.
Specifications of Electro-acupuncture Therapy Device
Model | SHD-I | SHD-II | SHD-III |
Wave forms | continuous wave, intermittent wave and dense-disperse wave | ||
Continuous wave | 1-100Hz adjustable | 0.8-100Hz adjustable | 0.8-100Hz adjustable |
Pulse width | 0.35ms±0.1ms | 0.5ms±0.1ms | 0.5ms±0.1ms |
Intermittent wave cycle | 2.3-6s adjustable | 6s | 6s |
Dense/disperse wave cycle | 2.3-6s adjustable | 6s | 6s |
Pulse intensity | 0-12Vpp | / | / |
Output channel | 5 channels output | 6 channels output | 4 channels output or 2 enhanced channels output |
Treatment time | 10-60min adjustable | 10-60min adjustable | 10-60min adjustable |
Size | 273*202*92mm | 273*202*92mm | 273*202*92mm |